Annals of Vascular Surgery
Volume 21, Issue 6 , Pages 671-675 , November 2007

Ultrasound Surveillance of Endovascular Aneurysm Repair: A Safe Modality versus Computed Tomography

  • John T. Collins

      Affiliations

    • Department of Surgery, Kalamazoo Center for Medical Studies, Michigan State University, Kalamazoo, MI
  • ,
  • Michael J. Boros

      Affiliations

    • Department of Surgery, Kalamazoo Center for Medical Studies, Michigan State University, Kalamazoo, MI
    • Corresponding Author InformationCorrespondence to: Michael J Boros, MD, Department of Surgery, Kalamazoo Center for Medical Studies, Michigan State University, 1000 Oakland Drive, Kalamazoo, MI 49008, USA
  • ,
  • Kristin Combs

      Affiliations

    • 1535 Gull Road, Suite 020, Kalamazoo, MI

References 

  1. Wolf YG, Johnson BL, Hill BB, Rubin GD, Forarty TJ, Zarins CK. Duplex ultrasound scanning versus computed tomographic angiography for postoperative evaluation of endovascular abdominal aortic aneurysm repair. J Vasc Surg. 2000;32:1142–1148
  2. Raman KG, Missig-Carroll N, Richardson T, Muluk SC, Makaraoun MS. Color-flow duplex ultrasound scan versus computed tomographic scan in the surveillance of endovascular aneurysm repair. J Vasc Surg. 2003;38:645–651
  3. Sato DT, Goff CD, Gregory RT, et al. Endoleak after aortic stent graft repair: diagnosis by color duplex ultrasound scan versus computed tomography scan. J Vasc Surg. 1998;28:657–663
  4. AbuRahma AF, Welch CA, Mullins BB, Dyer B. Computed tomographys versus color duplex ultrasound for surveillance of abdominal aortic stent-grafts. J Endovasc Ther. 2005;12:568–573
  5. Napoli V, Bargellini I, Sardella SG, et al. Abdominal aortic aneurysm: contrast-enhanced US for missed endoleaks alter endoluminal repair. Radiology. 2004;233:217–225
  6. Arko FR, Filis KA, Heikkinen MA, Johnson BL, Zarins CK. Duplex scanning after endovascular aneurysm repair: an alternative to computed tomograpy. Semin Vasc Surg. 2004;17:161–165
  7. Elkouri S, Panneton JM, Andrews JC, et al. Computed tomography and ultrasound in follow-up of patients after endovascular repair of abdominal aortic aneurysm. Ann Vasc Surg. 2004;18:271–279
  8. Ashoke R, Brown LC, Rodway A, et al. Color duplex ultrasonography is insensitive for the detection of endoleak after aortic endografting: a systematic review. J Endovasc Ther. 2005;12:297–305
  9. Hiatt MD, Rubin GD. Surveillance for endoleaks: how to detect all of them. Semin Vasc Surg 17:268-278.

 Presented at the Seventeenth Annual Winter Meeting of the Peripheral Vascular Surgery Society, Steamboat Springs, CO, January 26-28, 2007.

PII: S0890-5096(07)00280-4

doi: 10.1016/j.avsg.2007.07.009

Annals of Vascular Surgery
Volume 21, Issue 6 , Pages 671-675 , November 2007