      Abstract

      Objective

      Treatment of aneurysmal type B aortic dissection (TBAD) often involves thoracic aortic endografting (TEVAR). However, persistent patency of the false lumen from type R entry flow is common and is associated with late complications including rupture. We describe nine patients with aneurysmal chronic TBADs and patent false lumens, seven despite prior TEVAR. The goal of the false lumen intercostal embolization in these patients was to achieve propagation of false lumen thrombosis (FLT) and to prevent spinal cord ischemia using a staged approach in the overall treatment of their complex aortic aneurysm.

      Methods

      A multicenter retrospective review was performed of all consecutive false lumen intercostal embolization procedures; nine were identified. Pre- and postoperative computed tomographic angiograms were compared. We hypothesized that embolization was safe and feasible treatment option. The primary outcome was procedural characteristics and spinal cord ischemia to establish safety and feasibility. Secondary outcomes included change in supraceliac patent false lumen length and other perioperative clinical outcomes.

      Results

      In total, 30 of 31 (97%) targeted false lumen intercostal arteries were successfully coiled. Median procedural time was 57 minutes (IQR [23-99]), median air kerma was 585 mGy (IQR [398-1644]), and median contrast dose was 141 ml (IQR [74-240]). After embolization, all patients demonstrated propagation of FLT, with mean false lumen length decreasing by 48% from 13.8 cm to 6.6 cm. There was no mortality associated with this procedure; two patients suffered a lumbar drain related complication; one with cerebrospinal fluid leak and one with a spinal hematoma that was managed conservatively with no neurological deficit. No other complications occurred.

      Conclusions

      In this review, false lumen intercostal coil embolization was technically feasible and did not result in any cases of spinal cord ischemia. The procedures required acceptable amounts of operative time, fluoroscopic dose, and contrast. All patients experienced propagation of false lumen thrombosis, and no long-term procedure-related morbidity was noted. More data will be required to ascertain whether this procedure is effective at halting type R entry flow, preventing future type II entry flow, and promoting aortic remodeling over time.

      Abbreviations:

      CTA (computed tomographic angiography), FLT (false lumen thrombosis), LOS (length of stay), MAP (mean arterial pressure), SCI (spinal cord ischemia), SVS (Society for Vascular Surgery), TBAD (type B aortic dissection), TEVAR (thoracic endovascular aortic repair)
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Annals of Vascular Surgery
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Dake M.D.
        • Thompson M.
        • Van Sambeek M.
        • Vermassen F.
        • Morales J.P.
        DISSECT: A new mnemonic-based approach to the categorization of aortic dissection.
        Eur J Vasc Endovasc Surg. 2013; 46: 175-190
        • Fanelli F.
        • Dake M.D.
        Standard of practice for the endovascular treatment of thoracic aortic aneurysms and type B dissections.
        Cardiovasc Intervent Radiol. 2009; 32: 849-860
        • Kim T.H.
        • Ko Y.G.
        • Kwon S.W.
        • Choi D.
        • Lee D.Y.
        • Shim W.H.
        • et al.
        Large false lumen area is a predictor of failed false lumen volume reduction after stent-graft repair in type B aortic dissection.
        J Endovasc Ther. 2014; 21: 697-706
        • Kang W.C.
        • Greenberk R.K.
        • Mastracci T.M.
        • Eagleton M.J.
        • Hernandez A.V.
        • et al.
        Endovascular repair of complicated chronic distal aortic dissections: intermediate outcomes and complications.
        J Thorac Cardiovasc Surg. 2011; 142: 1074-1083
        • Sigman M.A.
        • Palmer O.P.
        • Ham S.W.
        • Cunningham M.
        • Weaver F.A.
        Aortic morphologic findings after thoracic endovascular aortic repair for type B aortic dissection.
        JAMA Surg. 2014; 149: 977-983
        • Lombardi J.V.
        • Hughes G.C.
        • Appoo J.J.
        • Bavaria J.E.
        • Beck A.W.
        • Cambria R.P.
        • Charlton-Ouw K.
        • Eslami M.H.
        • Kim K.M.
        • Leshnower B.G.
        • Maldonado T.
        • Reece T.B.
        • Wang G.J.
        Society for Vascular Surgery (SVS) and Society of Thoracic Surgeons (STS) reporting standards for type B aortic dissections.
        J Vasc Surg. 2020 Mar; 71 (Epub 2020 Jan 27. PMID: 32001058): 723-747https://doi.org/10.1016/j.jvs.2019.11.013
        • O'Callaghan A.
        • Mastracci T.M.
        • Eagleton M.J.
        Staged endovascular repair of thoracoabdominal aortic aneurysms limits incidence and severity of spinal cord ischemia.
        J Vasc Surg. 2015 Feb; 61 (Epub 2014 Oct 23. PMID: 25449006): 347-354.e1https://doi.org/10.1016/j.jvs.2014.09.011
        • Geisbusch S.
        • Stefanovic A.
        • Koruth J.S.
        • Lin H.M.
        • Morgello S.
        • Weisz D.J.
        • et al.
        Endovascular coil embolization of segmental arteries prevents paraplegia after subsequent thoracoabdominal aneurysm repair: an experimental model.
        J Thorac Cardiovasc Surg. 2014; 147: 220-227
        • Luehr M.
        • Salameh A.
        • Haunschild J.
        • Hoyer A.
        • Girrbach F.F.
        • von Aspern K.
        • et al.
        Minimally invasive segmental artery coil embolization for preconditioning of the spinal cord collateral network before one-stage descending and thoracoabdominal aneurysm repair.
        Innovations. 2014; 9: 60-65
        • Magee G.A.
        • Yi J.A.
        • Kuwayama D.P.
        Intercostal artery embolization to induce false lumen thrombosis in type B aortic dissection.
        J Vasc Surg Cases Innov Tech. 2020 Jun 25; 6 (PMID: 32775849; PMCID: PMC7396825): 433-437https://doi.org/10.1016/j.jvscit.2020.05.012
        • Schwartz S.I.
        • Durham C.
        • Clouse W.D.
        • Patel V.I.
        • Lancaster R.T.
        • Cambria R.P.
        • et al.
        Predictors of late aortic intervention in patients with medically treated type B aortic dissection.
        J Vasc Surg. 2018; 67: 78-84
        • Spinelli D.
        • Benedetto F.
        • Donato R.
        • Piffaretti G.
        • Marrocco-Trischitta M.M.
        • Patel H.J.
        • et al.
        Current evidence in predictors of aortic growth and events in acute type B aortic dissection.
        J Vasc Surg. 2018; ([published online ahead of print)
        • Liu F.
        • Ge Y.Y.
        • Guo W.
        • Liu X.P.
        • Jia X.
        • Xiong J.
        • et al.
        Preoperative thoracic false lumen branches are predictors of aortic enlargement after stent grafting for DeBakey IIIb aortic dissection.
        J Thorac Cardiovasc Surg. 2018; 155: 21-29
        • Kitamura T.
        • Torii S.
        • Oka N.
        • Horai T.
        • Nakashima K.
        • Itatani K.
        • et al.
        Key success factors for thoracic endovascular aortic repair for non-acute Stanford type B aortic dissection.
        Eur J Cardiothorac Surg. 2014; 46: 432-437
        • Naim W.
        • Ganesan P.B.
        • Sun Z.
        • Lei J.
        • Jansen S.
        • Hashin S.A.
        • et al.
        Flow pattern analysis in type B aortic dissection patients after stent-grafting repair: comparison between complete and incomplete false lumen thrombosis.
        Int J Numer Meth Biomed Eng. 2018; 34e2961
        • Kolbel T.
        • Carpenter S.W.
        • Lohrenz C.
        • Tsilimparis N.
        • Larena-Avellaneda A.
        • Debus E.S.
        Addressing persistent false lumen flow in chronic aortic dissection: the knickerbocker technique.
        J Endovasc Ther. 2014; 21: 117-122
        • Rohlffs F.
        • Tsilimparis N.
        • Fiorucci B.
        • Heidemann F.
        • Debus E.S.
        • Kolbel T.
        The candy-plug technique: technical aspects and early results of a new endovascular methods for false lumen occlusion in chronic aortic dissection.
        J Endovasc Ther. 2017; 24: 549-555
        • Hofferberth S.C.
        • Nixon I.K.
        • Mossop P.J.
        Aortic false lumen thrombosis induction by embolotherapy (AFTER) following endovascular repair of aortic dissection.
        J Endovasc Ther. 2012; 19: 538-545
        • Tripodi P.
        • Mestres G.
        • Briceño M.
        • Monterrosas O.G.
        • Riambau V.
        New Indications for Vascular Occluders in Secondary Repairs of Complex Aortic Pathologies.
        Ann Vasc Surg. 2017; 39 (285.e9-285.e15)
        • Yuan X.
        • Mitsis A.
        • Semple T.
        • Verdes M.C.
        • Cambronero-Cortinas E.
        • Tang Y.
        • et al.
        False lumen intervention to promote remodelling and thrombosis - the FLIRT concept in aortic dissection.
        Catheter Cardiovasc Interv. 2018; 00: 1-9
        • San Norberto E.M.
        • Taylor J.
        • Vaquero C.
        Aortic false lumen thrombosis and remodeling: the paradigm for endovascular repair of aortic dissection.
        J Endovasc Ther. 2012; 19: 546-548
        • Branzan D.
        • Etz C.D.
        • Moche M.
        • Von Aspern K.
        • Staab H.
        • Fuchs J.
        • et al.
        Ischaemic preconditioning of the spinal cord to prevent spinal cord ischaemia during endovascular repair of thoracoabdominal aortic aneurysm: First clinical experience.
        EuroIntervention. 2018; 14: 828-835
        • Maitrias P.
        • Mage A.
        • Belhomme D.
        • Reix T.
        Type II endoleak after endoluminal repair of thoracic aortic aneurysm associated with native coarctation.
        Interact Cardiovasc Thorac Surg. 2017; 24: 304-306
        • Mussa F.F.
        • Maldonado T.S.
        • Schwartz C.F.
        Percutaneous embolization of patent intercostal artery causing persistent type II endoleak and sac enlargement of thoracoabdominal aneurysm 2 years after hybrid repair.
        J Thorac Cardiovasc Surg. 2012; 144: e102-e106
        • Blakeslee-Carter J.
        • Potter H.A.
        • Banks C.A.
        • Passman M.
        • Pearce B.
        • McFarland G.
        • et al.
        Aortic visceral segment instability is evident following thoracic endovascular aortic repair for acute and subacute type B aortic dissection.
        J Vasc Surg. 2022; (Epub ahead of print)https://doi.org/10.1016/j.jvs.2022.02.046
        • Lombardi J.V.
        • Hughes G.C.
        • Appoo J.J.
        • Maldonado T.
        • Reece T.B.
        • Wang G.J.
        • et al.
        Society for Vascular Surgery (SVS) and Society of Thoracic Surgeons (STS) reporting standards for type B aortic dissections.
        J Vasc Surg. 2020; 71: 723-747